Assessment Year | 1994 |
---|---|
Principal Product | Plastic |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
37,500
ft2
|
Annual Production | 5,000,000
lb
|
Production Hrs. Annual | 5,950
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $149,825 | 2,327,081 |
kWh
|
$0.064 |
Other Energy | $30,406 | 4,274 |
MMBtu
|
$7.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $110,104 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,944 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Primary Product Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,610 | $5,358 |
$2,610
38,687
kWh
|
- | |
02 | 2.7135: Install occupancy sensors | $165 | $228 |
$165
3,810
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $3,247 | $1,883 |
$3,247
51,583
kWh
|
- | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,087 | $1,100 |
$3,087
48,945
kWh
|
- | |
05 | 2.4226: Use / purchase optimum sized compressor | $496 | $1,200 |
$496
5,862
kWh
|
- | |
06 | 4.631: Install an uninteruptable power supply | $100,000 | $8,200 | - | $100,000 | |
07 | 2.2136: Install / repair insulation on steam lines | $499 | $244 |
$499
20,809
kWh
|
- | |
TOTAL RECOMMENDED | $110,104 | $18,213 |
$10,104
169,696
kWh
|
$100,000 | ||
TOTAL IMPLEMENTED | $8,944 | $8,341 |
$8,944
139,215
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs