| Assessment Year | 1994 |
|---|---|
| Principal Product | Corrugated Boxes |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
227,000
ft2
|
| Annual Production | 57,000
thousand feet
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Florida |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $347,271 | 6,259,965 |
kWh
|
$0.055 |
| Natural Gas | $81,127 | 13,677 |
MMBtu
|
$5.93 |
| Fuel Oil #2 | $139,721 | 45,391 |
MMBtu
|
$3.08 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $397,573 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $84,723 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,227 | $20,158 |
$12,227
214,537
kWh
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $906 | $1,764 |
$906
17,292
kWh
|
- | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $256 | $360 |
$256
2,931
kWh
|
- | - | - | |
| 04 | 2.4133: Use most efficient type of electric motors | $18,485 | $9,481 |
$18,485
324,443
kWh
|
- | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,645 | $1,725 |
$3,645
63,892
kWh
|
- | - | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $9,113 | $6,574 |
$9,113
159,730
kWh
|
- | - | - | |
| 07 | 2.3413: Burn fossil fuel to produce steam to drive a steam turbine-generator and use steam exhaust for heat | $299,768 | $1,200,000 |
$481,507
8,985,639
kWh
|
$(-181,739.0)
-
MMBtu
|
- | - | |
| 08 | 2.2135: Repair and eliminate steam leaks | $2,279 | $1,200 | - | - |
$2,279
-
MMBtu
|
- | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $312 | $200 |
$312
5,569
kWh
|
- | - | - | |
| 10 | 2.4221: Install compressor air intakes in coolest locations | $1,514 | $500 |
$1,514
26,671
kWh
|
- | - | - | |
| 11 | 4.631: Install an uninteruptable power supply | $37,500 | $25,000 | - | - | - | $37,500 | |
| 12 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $11,568 | $4,642 |
$11,568
202,814
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $397,573 | $1,271,604 |
$539,533
10,003,518
kWh
|
$(-181,739.0)
-
MMBtu
|
$2,279
-
MMBtu
|
$37,500 | ||
| TOTAL IMPLEMENTED | $84,723 | $66,462 |
$44,944
788,394
kWh
|
- |
$2,279
-
MMBtu
|
$37,500 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | LPG Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs