Assessment Year 1993
Principal Product Aluminum Patio Furniture
NAICS
n/a
SIC 2514: Metal Household Furniture
Sales Range $10
M
to 50
M
# of Employees 160
Plant Area 650,000
ft2
Annual Production 35,000
pieces
Production Hrs. Annual 3,770
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $142,055 1,929,074
kWh
Natural Gas $38,809 6,747
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $16,915 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,491

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3137: Use power during off-peak periods $3,864 - $3,864
-
kWh
-
02 2.4133: Use most efficient type of electric motors $2,583 $4,808 $2,583
34,877
kWh
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $522 $705 $522
7,034
kWh
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $347 $675 $347
4,689
kWh
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,005 $2,000 $4,005
54,220
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $908 $1,386 $908
12,309
kWh
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,010 $8,108 $2,010
27,257
kWh
-
08 2.7135: Install occupancy sensors $667 $256 $667
9,086
kWh
-
09 2.7232: Replace existing hvac unit with high efficiency model $528 $1,070 $528
7,034
kWh
-
10 2.7261: Install timers and/or thermostats $745 $2,205 $745
16,706
kWh
-
11 2.2414: Use waste heat from hot flue gases to preheat $736 $2,600 - $736
-
MMBtu
TOTAL RECOMMENDED $16,915 $23,813 $16,179
173,212
kWh
$736
-
MMBtu
TOTAL IMPLEMENTED $3,491 $6,194 $3,491
47,186
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs