Assessment Year 1993
Principal Product Newspaper
NAICS
n/a
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range $5
M
to 10
M
# of Employees 320
Plant Area 62,000
ft2
Annual Production 27,375,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $263,545 3,804,220
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $114,496 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $42,942

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,012 $2,142 $1,012
14,654
kWh
02 2.7144: Install spectral reflectors / delamp $20,185 $28,015 $20,185
242,087
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $354 $1,320 $354
1,758
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $512 $130 $512
7,327
kWh
05 2.7232: Replace existing hvac unit with high efficiency model $14,911 $17,020 $14,911
216,002
kWh
06 2.4133: Use most efficient type of electric motors $9,228 $9,376 $9,228
133,646
kWh
07 2.7491: Insulate glazing, walls, ceilings, and roofs $28,637 $77,160 $28,637
415,006
kWh
08 2.4224: Upgrade controls on compressors $17,131 $1,500 $17,131
248,242
kWh
09 2.7271: Replace electric reheat with heat pipes $21,866 $22,500 $21,866
122,802
kWh
10 2.3137: Use power during off-peak periods $660 - $660
-
kWh
TOTAL RECOMMENDED $114,496 $159,163 $114,496
1,401,524
kWh
TOTAL IMPLEMENTED $42,942 $30,038 $42,942
612,544
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings