Assessment Year 1993
Principal Product Newspapers
NAICS
n/a
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range $10
M
to 50
M
# of Employees 225
Plant Area 70,000
ft2
Annual Production 21,900,000
pieces
Production Hrs. Annual 8,736
hrs
Location (State) Florida

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $248,114 3,537,222
kWh
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $53,719 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,427

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $3,727 $3,429 $3,727
53,341
kWh
02 2.7144: Install spectral reflectors / delamp $13,230 $26,355 $13,230
145,369
kWh
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,585 $4,022 $1,585
22,567
kWh
04 2.7142: Utilize higher efficiency lamps and/or ballasts $72 $30 $72
879
kWh
05 2.7232: Replace existing hvac unit with high efficiency model $14,700 $22,000 $14,700
210,141
kWh
06 2.7271: Replace electric reheat with heat pipes $11,340 $7,000 $11,340
162,075
kWh
07 2.4221: Install compressor air intakes in coolest locations $595 $150 $595
8,499
kWh
08 2.4231: Reduce the pressure of compressed air to the minimum required $8,470 $10,400 $8,470
121,043
kWh
TOTAL RECOMMENDED $53,719 $73,386 $53,719
723,914
kWh
TOTAL IMPLEMENTED $18,427 $25,429 $18,427
263,482
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs