| Assessment Year | 2026 |
|---|---|
| Principal Product | Cookies and Crackers |
| NAICS | 311821: Cookie and Cracker Manufacturing |
| SIC | 2052: Cookies and Crackers |
| Sales Range | $100 M to 500M |
| # of Employees | 135 |
| Plant Area |
14,245
ft2
|
| Annual Production | 14,222,596
lb
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $322,947 | 4,376,943 |
kWh
|
$0.074 | |
| Electricity Demand | $33,577 | 8,513 |
kW-mo/yr
|
$3.94 | |
| Electricity Fees | $2,700 | - |
|
- | |
| Natural Gas | $134,951 | 24,322 |
MMBtu
|
$5.55 | |
| Waste Disposal Costs | |||||
| Water Usage | $19,435 | 3,710 |
Tgal
|
$5.24 | |
| Water Disposal | $12,914 | 2,049 |
Tgal
|
$6.30 | |
| Other Liquid (non-haz) | $1,754 | 1 |
gal
|
$1,754.00 | |
| TOTAL YEARLY COSTS | $528,278 | ||||
| RECOMMENDED SAVINGS* | $64,222 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,844 | - |
$4,408
49,286
kWh
|
$436
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.6121: Reduce hot water temperature to the minimum required | $31,563 | - | - | - |
$31,563
-
MMBtu
|
- | - | |
| 03 | 3.4156: Use flow control valves on equipment to optimize water use | $9,875 | $528 | - | - | - |
$4,484
-
Tgal
|
$5,391
-
Tgal
|
|
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $13,680 | - |
$12,601
170,744
kWh
|
$1,079
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $1,310 | $2,150 |
$1,206
16,303
kWh
|
$104
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $2,950 | $8,050 |
$(-412.0)
(-5,584)
kWh
|
$(-35.0)
-
kW-mo/yr
|
$3,397
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $64,222 | $10,728 |
$17,803
230,749
kWh
|
$1,584
-
kW-mo/yr
|
$34,960
-
MMBtu
|
$4,484
-
Tgal
|
$5,391
-
Tgal
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs