ITAC Assessment: UD1150
ITAC logo
ITAC Assessment: UD1150
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Cookies and Crackers
NAICS 311821: Cookie and Cracker Manufacturing
SIC 2052: Cookies and Crackers
Sales Range $100
M
to 500
M
# of Employees 135
Plant Area 14,245
ft2
Annual Production 14,222,596
lb
Production Hrs. Annual 7,488
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $322,947 4,376,943
kWh
Electricity Demand $33,577 8,513
kW-mo/yr
Electricity Fees $2,700 -
Natural Gas $134,951 24,322
MMBtu
Waste Disposal Costs
Water Usage $19,435 3,710
Tgal
Water Disposal $12,914 2,049
Tgal
Other Liquid (non-haz) $1,754 1
gal
TOTAL YEARLY COSTS $528,278
RECOMMENDED SAVINGS* $64,222 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Water Disposal Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $4,844 - $4,408
49,286
kWh
$436
-
kW-mo/yr
- - -
02 2.6121: Reduce hot water temperature to the minimum required $31,563 - - - $31,563
-
MMBtu
- -
03 3.4156: Use flow control valves on equipment to optimize water use $9,875 $528 - - - $4,484
-
Tgal
$5,391
-
Tgal
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $13,680 - $12,601
170,744
kWh
$1,079
-
kW-mo/yr
- - -
05 2.4221: Install compressor air intakes in coolest locations $1,310 $2,150 $1,206
16,303
kWh
$104
-
kW-mo/yr
- - -
06 2.2414: Use waste heat from hot flue gases to preheat $2,950 $8,050 $(-412.0)
(-5,584)
kWh
$(-35.0)
-
kW-mo/yr
$3,397
-
MMBtu
- -
TOTAL RECOMMENDED $64,222 $10,728 $17,803
230,749
kWh
$1,584
-
kW-mo/yr
$34,960
-
MMBtu
$4,484
-
Tgal
$5,391
-
Tgal
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Usage Savings Water Disposal Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs