| Assessment Year | 2005 |
|---|---|
| Principal Product | Industrial and Automotive Gasket |
| NAICS | 336350: Motor Vehicle Transmission and Power Train Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $50 M to 100M |
| # of Employees | 254 |
| Plant Area |
80,000
ft2
|
| Annual Production | 40,000,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $297,737 | 11,991,000 |
kWh
|
$0.025 |
| Electricity Demand | $157,950 | 26,660 |
kW-mo/yr
|
$5.92 |
| Electricity Fees | $151,959 | - |
|
- |
| Natural Gas | $1,790 | 164 |
MMBtu
|
$10.91 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $50,686 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $234 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.5218: Reuse / recycle/ sell rubber products | $22,000 | $6,600 | - | - | - |
$22,000
-
lb
|
- | - | |
| 02 | 2.3137: Use power during off-peak periods | $21,518 | $6,899 | - |
$21,518
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.7135: Install occupancy sensors | $1,148 | $582 |
$546
22,022
kWh
|
$602
-
kW-mo/yr
|
- | - | - | - | |
| 04 | 2.6232: Install set-back timers | $896 | $1,540 | - | - |
$896
-
MMBtu
|
- | - | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $234 | $530 |
$334
13,463
kWh
|
- | - | - | $(-100.0) | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $725 | $480 |
$202
8,273
kWh
|
$66
-
kW-mo/yr
|
- | - | $180 | $277 | |
| 07 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,165 | $36,140 | - |
$4,165
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $50,686 | $52,771 |
$1,082
43,758
kWh
|
$26,351
-
kW-mo/yr
|
$896
-
MMBtu
|
$22,000
-
lb
|
$80 | $277 | ||
| TOTAL IMPLEMENTED | $234 | $530 |
$334
13,463
kWh
|
- | - | - | $(-100.0) | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs