ITAC Assessment: UD1086
ITAC logo
ITAC Assessment: UD1086
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Hydraulic Pumps
NAICS 333996: Fluid Power Pump and Motor Manufacturing
SIC 3594: Fluid Power Pumps and Motors
Sales Range $100
M
to 500
M
# of Employees 65
Plant Area 155,322
ft2
Annual Production 4,709
units
Production Hrs. Annual 4,350
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $217,731 4,583,353
kWh
Electricity Demand $80,772 11,938
kW-mo/yr
Electricity Fees $7,847 -
Natural Gas $32,946 5,556
MMBtu
Waste Disposal Costs
Water Usage $5,356 917
Tgal
Water Disposal $8,158 917
Tgal
Other Liquid (non-haz) $15,297 1
gal
TOTAL YEARLY COSTS $368,107
RECOMMENDED SAVINGS* $70,647 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7111: Reduce illumination to minimum necessary levels $12,814 - $9,162
192,883
kWh
$3,652
-
kW-mo/yr
- - - - -
02 2.7124: Make a practice of turning off lights when not needed $573 - $411
8,654
kWh
- - - - $133 $29
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $54 - $45
957
kWh
$9
-
kW-mo/yr
- - - - -
04 2.7233: Use properly designed and sized hvac equipment $13,233 - $14,371
302,541
kWh
$2,381
-
kW-mo/yr
- $(-3,519.0)
-
MMBtu
- - -
05 2.7224: Reduce space conditioning during non-working hours $8,962 $7,238 $2,917
61,403
kWh
- - $6,045
-
MMBtu
- - -
06 2.6231: Utilize controls to operate equipment only when needed $561 - $561
11,817
kWh
- - - - - -
07 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $10,965 $1,068 $9,142
192,453
kWh
$1,823
-
kW-mo/yr
- - - - -
08 2.4239: Eliminate or reduce compressed air usage $4,780 - $4,780
100,640
kWh
- - - - - -
09 2.4239: Eliminate or reduce compressed air usage $4,459 $7,620 $4,459
93,877
kWh
- - - - - -
10 2.3212: Optimize plant power factor $7,429 $25,300 - - $7,429 - - - -
11 3.4116: Meter recycled water (to reduce sewer charges) $6,817 - - - - - $6,817
-
Tgal
- -
TOTAL RECOMMENDED $70,647 $41,226 $45,848
965,225
kWh
$7,865
-
kW-mo/yr
$7,429 $2,526
-
MMBtu
$6,817
-
Tgal
$133 $29
TOTAL IMPLEMENTED - - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Water Disposal Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs