Assessment Year | 2023 |
---|---|
Principal Product | Brake Hose Assemblies |
NAICS | 336340: Motor Vehicle Brake System Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 204 |
Plant Area |
300,000
ft2
|
Annual Production | 3,000,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $272,331 | 5,845,371 |
kWh
|
$0.047 | |
Electricity Demand | $67,530 | 13,348 |
kW-mo/yr
|
$5.06 | |
Electricity Fees | $10,361 | - |
|
- | |
Natural Gas | $40,551 | 5,120 |
MMBtu
|
$7.92 | |
Waste Disposal Costs | |||||
Water Usage | $18,461 | 2,647 |
Tgal
|
$6.97 | |
Water Disposal | $21,051 | 2,647 |
Tgal
|
$7.95 | |
TOTAL YEARLY COSTS | $430,285 | ||||
RECOMMENDED SAVINGS* | $44,866 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $18,950 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $9,795 | $480 |
$8,527
182,979
kWh
|
$1,268
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $332 | $1,200 |
$204
4,379
kWh
|
$128
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7241: Install outside air damper / economizer on hvac unit | $9,326 | $2,880 |
$9,326
200,130
kWh
|
- | - | - | - | - | |
04 | 2.7444: Close holes and openings in building such as broken windows | $133 | $413 | - | - | - |
$133
-
MMBtu
|
- | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $2,173 | - |
$2,173
46,627
kWh
|
- | - | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,974 | $952 |
$1,514
32,500
kWh
|
$460
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $767 | $3,117 |
$767
16,459
kWh
|
- | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,676 | $13,290 |
$2,231
47,873
kWh
|
$1,397
-
kW-mo/yr
|
- | - | $423 | $625 | |
09 | 2.2628: Utilize a less expensive cooling method | $8,273 | $24,175 |
$6,346
136,183
kWh
|
$1,927
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.3212: Optimize plant power factor | $7,417 | $31,038 | - | - | $7,417 | - | - | - | |
TOTAL RECOMMENDED | $44,866 | $77,545 |
$31,088
667,130
kWh
|
$5,180
-
kW-mo/yr
|
$7,417 |
$133
-
MMBtu
|
$423 | $625 | ||
TOTAL IMPLEMENTED | $18,950 | $15,922 |
$14,649
314,358
kWh
|
$3,253
-
kW-mo/yr
|
- | - | $423 | $625 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs