Assessment Year | 2020 |
---|---|
Principal Product | Milk, Cottage Cheese, Sour Cream, Yogurts, Beverages |
NAICS | 311511: Fluid Milk Manufacturing |
SIC | 2026: Fluid Milk |
Sales Range | $100 M to 500M |
# of Employees | 145 |
Plant Area |
120,000
ft2
|
Annual Production | 217,049,025
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $565,239 | 12,560,865 |
kWh
|
$0.045 | |
Electricity Demand | $99,219 | 26,388 |
kW-mo/yr
|
$3.76 | |
Electricity Fees | $387,690 | - |
|
- | |
Natural Gas | $247,589 | 56,000 |
MMBtu
|
$4.42 | |
Waste Disposal Costs | |||||
Water Usage | $118,650 | 57,721 |
Tgal
|
$2.06 | |
Water Disposal | $222,824 | 54,599 |
Tgal
|
$4.08 | |
TOTAL YEARLY COSTS | $1,641,211 | ||||
RECOMMENDED SAVINGS* | $146,514 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $28,500 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,326 | - | - | - |
$1,326
-
MMBtu
|
- | |
02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $45,294 | $7,500 |
$40,642
903,156
kWh
|
$4,652
-
kW-mo/yr
|
- | - | |
03 | 2.2696: Use excess cold process fluid for industrial cooling needs | $23,635 | - |
$21,208
471,288
kWh
|
$2,427
-
kW-mo/yr
|
- | - | |
04 | 2.2696: Use excess cold process fluid for industrial cooling needs | $15,013 | $21,000 |
$2,838
63,072
kWh
|
- |
$12,175
-
MMBtu
|
- | |
05 | 2.2511: Insulate bare equipment | $28,500 | $18,326 | - | - |
$28,500
-
MMBtu
|
- | |
06 | 2.2511: Insulate bare equipment | $4,569 | $309 |
$4,100
91,104
kWh
|
$469
-
kW-mo/yr
|
- | - | |
07 | 2.2511: Insulate bare equipment | $1,509 | $2,357 | - | - |
$1,509
-
MMBtu
|
- | |
08 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $6,203 | $7,500 |
$1,203
26,732
kWh
|
- | - | $5,000 | |
09 | 2.4224: Upgrade controls on compressors | $4,307 | $10,000 |
$3,863
85,848
kWh
|
$444
-
kW-mo/yr
|
- | - | |
10 | 2.4224: Upgrade controls on compressors | $2,657 | $1,120 |
$2,287
50,831
kWh
|
$370
-
kW-mo/yr
|
- | - | |
11 | 2.4323: Use optimum size and capacity equipment | $1,972 | $5,000 |
$1,698
37,741
kWh
|
$274
-
kW-mo/yr
|
- | - | |
12 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,907 | $28,900 |
$6,917
153,702
kWh
|
$990
-
kW-mo/yr
|
- | - | |
13 | 2.7135: Install occupancy sensors | $3,028 | $10,386 |
$1,336
29,690
kWh
|
$153
-
kW-mo/yr
|
- | $1,539 | |
14 | 2.7135: Install occupancy sensors | $594 | $1,213 |
$312
6,935
kWh
|
$36
-
kW-mo/yr
|
- | $246 | |
TOTAL RECOMMENDED | $146,514 | $113,611 |
$86,404
1,920,099
kWh
|
$9,815
-
kW-mo/yr
|
$43,510
-
MMBtu
|
$6,785 | ||
TOTAL IMPLEMENTED | $28,500 | $18,326 | - | - |
$28,500
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs