ITAC Assessment: SF0034
ITAC logo
ITAC Assessment: SF0034
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Advertisement Inserts
NAICS
n/a
SIC 2752: Commercial Printing, Lithographic
Sales Range $50
M
to 100
M
# of Employees 200
Plant Area 90,000
ft2
Annual Production 45,000
ton
Production Hrs. Annual 8,640
hrs
Location (State) California

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $782,570 8,007,620
kWh
Natural Gas $364,820 86,806
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $88,909 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $45,625

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.3212: Optimize plant power factor $6,480 $11,289 $6,480
-
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $8,729 $7,007 $8,729
89,390
kWh
-
03 2.4133: Use most efficient type of electric motors $2,330 $1,862 $2,330
23,740
kWh
-
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $22,567 $17,310 $22,567
230,950
kWh
-
05 2.7145: Install skylights $8,677 $28,600 $8,677
88,804
kWh
-
06 2.4231: Reduce the pressure of compressed air to the minimum required $5,539 $750 $5,539
56,565
kWh
-
07 2.4239: Eliminate or reduce compressed air usage $15,345 $1,600 $15,345
157,093
kWh
-
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,999 $900 $11,999
122,802
kWh
-
09 2.2511: Insulate bare equipment $5,517 $2,939 - $5,517
-
MMBtu
10 2.4322: Use or replace with energy efficient substitutes $1,726 $1,191 $1,726
17,585
kWh
-
TOTAL RECOMMENDED $88,909 $73,448 $83,392
786,929
kWh
$5,517
-
MMBtu
TOTAL IMPLEMENTED $45,625 $27,079 $45,625
466,882
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs