Assessment Year | 2018 |
---|---|
Principal Product | Molded Rubber Goods |
NAICS | 326299: All Other Rubber Product Manufacturing |
SIC | 3061: Molded, Extruded, and Lathe-Cut Mechanical Rubber Goods |
Sales Range | $5 M to 10M |
# of Employees | 120 |
Plant Area |
19,200
ft2
|
Annual Production | 173,452
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $149,528 | 2,254,644 |
kWh
|
$0.066 | |
Electricity Demand | $2,129 | 364 |
kW-mo/yr
|
$5.85 | |
Electricity Fees | $37,278 | - |
|
- | |
Natural Gas | $3,378 | 423 |
MMBtu
|
$7.99 | |
Waste Disposal Costs | |||||
Water Usage | $2,101 | 409 |
Tgal
|
$5.13 | |
Water Disposal | $540 | 409 |
Tgal
|
$1.32 | |
TOTAL YEARLY COSTS | $194,954 | ||||
RECOMMENDED SAVINGS* | $98,988 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $28,289 | - |
$28,289
426,563
kWh
|
- | |
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $8,337 | - |
$8,337
125,705
kWh
|
- | |
03 | 2.6218: Turn off equipment when not in use | $37,147 | - |
$36,063
543,775
kWh
|
$1,084
-
kW-mo/yr
|
|
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $467 | - | - |
$467
-
kW-mo/yr
|
|
05 | 2.2625: Chill water to the highest temperature possible | $455 | - |
$389
5,866
kWh
|
$66
-
kW-mo/yr
|
|
06 | 2.4239: Eliminate or reduce compressed air usage | $7,962 | $2,000 |
$6,807
102,637
kWh
|
$1,155
-
kW-mo/yr
|
|
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,246 | $2,080 |
$3,483
53,109
kWh
|
$763
-
kW-mo/yr
|
|
08 | 2.4239: Eliminate or reduce compressed air usage | $353 | $50 |
$302
4,584
kWh
|
$51
-
kW-mo/yr
|
|
09 | 2.4221: Install compressor air intakes in coolest locations | $193 | $500 |
$165
2,484
kWh
|
$28
-
kW-mo/yr
|
|
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,539 | $17,808 |
$9,864
148,739
kWh
|
$1,675
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $98,988 | $22,438 |
$93,699
1,413,462
kWh
|
$5,289
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs