Assessment Year | 2018 |
---|---|
Principal Product | Pumps |
NAICS | 333911: Pump and Pumping Equipment Manufacturing |
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $50 M to 100M |
# of Employees | 175 |
Plant Area |
191,000
ft2
|
Annual Production | 72,258
units
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $134,287 | 2,827,092 |
kWh
|
$0.048 | |
Electricity Demand | $124,441 | 8,214 |
kW-mo/yr
|
$15.15 | |
Electricity Fees | $780 | - |
|
- | |
Natural Gas | $14,172 | 1,485 |
MMBtu
|
$9.54 | |
Waste Disposal Costs | |||||
Water Usage | $10,069 | 918 |
Tgal
|
$10.97 | |
Water Disposal | $9,008 | 918 |
Tgal
|
$9.81 | |
TOTAL YEARLY COSTS | $292,757 | ||||
RECOMMENDED SAVINGS* | $51,006 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $49,748 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,113 | - |
$2,113
44,474
kWh
|
- | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,260 | $1,000 |
$1,989
43,641
kWh
|
$1,271
-
kW-mo/yr
|
- | - | - | |
03 | 2.4323: Use optimum size and capacity equipment | $957 | $2,500 |
$666
14,016
kWh
|
$291
-
kW-mo/yr
|
- | - | - | |
04 | 2.4239: Eliminate or reduce compressed air usage | $938 | - |
$574
12,840
kWh
|
$364
-
kW-mo/yr
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $320 | $1,500 |
$223
4,688
kWh
|
$97
-
kW-mo/yr
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,998 | $55,816 |
$2,589
54,510
kWh
|
$3,964
-
kW-mo/yr
|
- | $6,445 | - | |
07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $30,420 | $25,000 | - | - |
$36,000
-
lb
|
$(-7,380.0) | $1,800 | |
TOTAL RECOMMENDED | $51,006 | $85,816 |
$8,154
174,169
kWh
|
$5,987
-
kW-mo/yr
|
$36,000
-
lb
|
$(-935.0) | $1,800 | ||
TOTAL IMPLEMENTED | $49,748 | $84,316 |
$7,357
156,641
kWh
|
$5,526
-
kW-mo/yr
|
$36,000
-
lb
|
$(-935.0) | $1,800 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs