Assessment Year | 2017 |
---|---|
Principal Product | Acrylonitrile, Acetonitrile, Hydrogen Cyanide |
NAICS | 325110: Petrochemical Manufacturing |
SIC | 2869: Industrial Organic Chemicals, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 300 |
Plant Area |
2,500,000
ft2
|
Annual Production | 360,000,000
lb
|
Production Hrs. Annual | 7,140
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $4,163,355 | 69,658,440 |
kWh
|
$0.060 | |
Natural Gas | $2,136,481 | 718,509 |
MMBtu
|
$2.97 | |
Waste Disposal Costs | |||||
Water Usage | $1,546,699 | 470,968 |
Tgal
|
$3.28 | |
Water Disposal | $85,930 | 25,486 |
Tgal
|
$3.37 | |
TOTAL YEARLY COSTS | $7,932,465 | ||||
RECOMMENDED SAVINGS* | $1,270,996 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $383,642 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2694: Use highest temperature for chilling or cold storage | $217,648 | $48,962 |
$186,784
3,125,058
kWh
|
- | $30,864 | |
02 | 2.7261: Install timers and/or thermostats | $12,245 | $25,000 |
$12,245
204,871
kWh
|
- | - | |
03 | 2.1116: Improve combustion control capability | $270,579 | $100,000 | - |
$270,579
-
MMBtu
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $8,225 | $4,000 |
$8,225
137,606
kWh
|
- | - | |
05 | 2.7291: Reschedule and rearrange multiple-source heating systems | $57,432 | $35,000 |
$57,432
960,887
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $14,748 | $4,000 |
$14,748
246,753
kWh
|
- | - | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $383,642 | $613,600 |
$383,642
6,418,640
kWh
|
- | - | |
08 | 2.3321: Use steam pressure reduction to generate power | $229,882 | $595,039 |
$275,310
4,588,488
kWh
|
- | $(-45,428.0) | |
09 | 2.3321: Use steam pressure reduction to generate power | $76,595 | $198,657 |
$91,914
1,532,124
kWh
|
- | $(-15,319.0) | |
TOTAL RECOMMENDED | $1,270,996 | $1,624,258 |
$1,030,300
17,214,427
kWh
|
$270,579
-
MMBtu
|
$(-29,883.0) | ||
TOTAL IMPLEMENTED | $383,642 | $613,600 |
$383,642
6,418,640
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs