Assessment Year 2017
Principal Product Acrylonitrile, Acetonitrile, Hydrogen Cyanide
NAICS 325110: Petrochemical Manufacturing
SIC 2869: Industrial Organic Chemicals, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 300
Plant Area 2,500,000
ft2
Annual Production 360,000,000
lb
Production Hrs. Annual 7,140
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $4,163,355 69,658,440
kWh
Natural Gas $2,136,481 718,509
MMBtu
Waste Disposal Costs
Water Usage $1,546,699 470,968
Tgal
Water Disposal $85,930 25,486
Tgal
TOTAL YEARLY COSTS $7,932,465
RECOMMENDED SAVINGS* $1,270,996 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $383,642

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.2694: Use highest temperature for chilling or cold storage $217,648 $48,962 $186,784
3,125,058
kWh
- $30,864
02 2.7261: Install timers and/or thermostats $12,245 $25,000 $12,245
204,871
kWh
- -
03 2.1116: Improve combustion control capability $270,579 $100,000 - $270,579
-
MMBtu
-
04 2.4322: Use or replace with energy efficient substitutes $8,225 $4,000 $8,225
137,606
kWh
- -
05 2.7291: Reschedule and rearrange multiple-source heating systems $57,432 $35,000 $57,432
960,887
kWh
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $14,748 $4,000 $14,748
246,753
kWh
- -
07 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $383,642 $613,600 $383,642
6,418,640
kWh
- -
08 2.3321: Use steam pressure reduction to generate power $229,882 $595,039 $275,310
4,588,488
kWh
- $(-45,428.0)
09 2.3321: Use steam pressure reduction to generate power $76,595 $198,657 $91,914
1,532,124
kWh
- $(-15,319.0)
TOTAL RECOMMENDED $1,270,996 $1,624,258 $1,030,300
17,214,427
kWh
$270,579
-
MMBtu
$(-29,883.0)
TOTAL IMPLEMENTED $383,642 $613,600 $383,642
6,418,640
kWh
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs