Assessment Year | 2017 |
---|---|
Principal Product | Sunroofs |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 380 |
Plant Area |
128,755
ft2
|
Annual Production | 1,096,625
units
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $263,110 | 3,556,000 |
kWh
|
$0.074 | |
Electricity Demand | $42,159 | 8,448 |
kW-mo/yr
|
$4.99 | |
Electricity Fees | $2,462 | - |
|
- | |
Natural Gas | $91,718 | 16,682 |
MMBtu
|
$5.50 | |
Waste Disposal Costs | |||||
Water Usage | $17,024 | 5,136 |
Tgal
|
$3.31 | |
Water Disposal | $29,294 | 5,132 |
Tgal
|
$5.71 | |
TOTAL YEARLY COSTS | $445,767 | ||||
RECOMMENDED SAVINGS* | $45,835 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $7,371 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $8,133 | $4,500 |
$8,133
109,694
kWh
|
- | - | - | |
02 | 2.7224: Reduce space conditioning during non-working hours | $4,232 | $400 | - | - |
$4,232
-
MMBtu
|
- | |
03 | 2.7224: Reduce space conditioning during non-working hours | $3,139 | - |
$3,139
42,342
kWh
|
- | - | - | |
04 | 2.1123: Install automatic stack damper | $1,358 | $548 | - | - |
$1,358
-
MMBtu
|
- | |
05 | 2.4226: Use / purchase optimum sized compressor | $8,870 | $37,000 |
$8,168
110,160
kWh
|
$702
-
kW-mo/yr
|
- | - | |
06 | 2.4235: Remove or close off unneeded compressed air lines | $5,095 | $4,624 |
$5,095
68,717
kWh
|
- | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,311 | - |
$4,193
56,549
kWh
|
$278
-
kW-mo/yr
|
- | $(-2,160.0) | |
08 | 2.4226: Use / purchase optimum sized compressor | $648 | - |
$481
6,486
kWh
|
$167
-
kW-mo/yr
|
- | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,428 | $3,701 |
$1,168
15,748
kWh
|
$260
-
kW-mo/yr
|
- | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,250 | $3,655 |
$1,840
24,821
kWh
|
$410
-
kW-mo/yr
|
- | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,727 | $21,847 |
$4,982
67,200
kWh
|
$555
-
kW-mo/yr
|
- | $190 | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,242 | $7,925 |
$1,774
23,929
kWh
|
$329
-
kW-mo/yr
|
- | $139 | |
13 | 2.7111: Reduce illumination to minimum necessary levels | $402 | $630 |
$362
4,885
kWh
|
$40
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $45,835 | $84,830 |
$39,335
530,531
kWh
|
$2,741
-
kW-mo/yr
|
$5,590
-
MMBtu
|
$(-1,831.0) | ||
TOTAL IMPLEMENTED | $7,371 | $400 |
$3,139
42,342
kWh
|
- |
$4,232
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |