Assessment Year 1993
Principal Product Custom blending of wax products
NAICS
n/a
SIC 2999: Products of Petroleum and Coal, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 50
Plant Area 45,000
ft2
Annual Production 0
units
Production Hrs. Annual 4,125
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $87,395 1,121,043
kWh
Natural Gas $98,965 31,516
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $14,464 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,876

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $4,147 $500 - $4,147
-
MMBtu
02 2.2443: Re-use or recycle hot or cold process exhaust air $484 $1,000 - $484
-
MMBtu
03 2.2511: Insulate bare equipment $525 $314 - $525
-
MMBtu
04 2.7142: Utilize higher efficiency lamps and/or ballasts $3,334 $3,400 $3,334
42,790
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $498 $1,063 $498
6,448
kWh
-
06 2.7135: Install occupancy sensors $482 $225 $482
6,155
kWh
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,739 $1,753 $1,739
22,274
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $265 - $265
3,517
kWh
-
09 2.3131: Reschedule plant operations or reduce load to avoid peaks $2,676 - $2,676
-
kWh
-
10 2.7224: Reduce space conditioning during non-working hours $314 $200 - $314
-
MMBtu
TOTAL RECOMMENDED $14,464 $8,455 $8,994
81,184
kWh
$5,470
-
MMBtu
TOTAL IMPLEMENTED $12,876 $6,941 $8,729
77,667
kWh
$4,147
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs