Assessment Year | 2016 |
---|---|
Principal Product | Flat Rolled Slit Coil |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
150,000
ft2
|
Annual Production | 79,504
ton
|
Production Hrs. Annual | 2,610
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,428 | 1,076,385 |
kWh
|
$0.051 |
Electricity Demand | $55,316 | 4,800 |
kW-mo/yr
|
$11.52 |
Electricity Fees | $781 | - |
|
- |
Natural Gas | $22,213 | 2,679 |
MMBtu
|
$8.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,943 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,270 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7442: Keep doors and windows shut when not on use | $5,504 | $500 | - | - |
$5,504
-
MMBtu
|
|
02 | 2.7224: Reduce space conditioning during non-working hours | $5,148 | $1,660 | - | - |
$5,148
-
MMBtu
|
|
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $776 | $400 |
$776
17,928
kWh
|
- | - | |
04 | 2.3212: Optimize plant power factor | $3,057 | $2,000 | - |
$3,057
-
kW-mo/yr
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $304 | - |
$143
3,309
kWh
|
$161
-
kW-mo/yr
|
- | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,478 | $77,725 |
$7,644
176,495
kWh
|
$9,834
-
kW-mo/yr
|
- | |
07 | 2.4151: Develop a repair/replace policy | $462 | $2,400 |
$217
5,016
kWh
|
$245
-
kW-mo/yr
|
- | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $214 | - |
$101
2,325
kWh
|
$113
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $32,943 | $84,685 |
$8,881
205,073
kWh
|
$13,410
-
kW-mo/yr
|
$10,652
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,270 | $2,900 |
$360
8,325
kWh
|
$406
-
kW-mo/yr
|
$5,504
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs