Assessment Year | 2015 |
---|---|
Principal Product | Vinyl Siding |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $100 M to 500M |
# of Employees | 151 |
Plant Area |
406,588
ft2
|
Annual Production | 85,000,000
lb
|
Production Hrs. Annual | 8,160
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,278,991 | 20,476,800 |
kWh
|
$0.062 |
Electricity Demand | $341,715 | 40,224 |
kW-mo/yr
|
$8.50 |
Natural Gas | $256,340 | 32,782 |
MMBtu
|
$7.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $574,754 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $145,219 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $56,347 | $2,000 | - | - |
$56,347
-
MMBtu
|
- | - | - | |
02 | 3.4116: Meter recycled water (to reduce sewer charges) | $6,953 | - | - | - | - |
$6,953
-
Tgal
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $38,906 | $1,200 |
$33,546
592,795
kWh
|
$5,360
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,861 | - |
$9,783
172,881
kWh
|
$1,678
-
kW-mo/yr
|
- | - | $(-600.0) | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $3,293 | $470 |
$3,293
58,189
kWh
|
- | - | - | - | - | |
06 | 2.2511: Insulate bare equipment | $22,071 | $7,500 |
$18,840
332,928
kWh
|
$3,231
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4113: Install motor voltage controller on lightly loaded motors | $16,794 | - |
$16,794
296,759
kWh
|
- | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28,134 | - |
$22,741
397,120
kWh
|
$3,900
-
kW-mo/yr
|
- | - | $1,493 | - | |
09 | 2.7135: Install occupancy sensors | $16,525 | $6,100 |
$14,340
253,394
kWh
|
$621
-
kW-mo/yr
|
- | - | $1,564 | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,695 | $67,200 |
$3,243
56,625
kWh
|
$556
-
kW-mo/yr
|
- | - | $(-104.0) | - | |
11 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $9,383 | - |
$8,741
154,455
kWh
|
$642
-
kW-mo/yr
|
- | - | - | - | |
12 | 2.2625: Chill water to the highest temperature possible | $4,382 | - |
$3,740
66,096
kWh
|
$642
-
kW-mo/yr
|
- | - | - | - | |
13 | 3.3122: Use filtration, centrifuging to remove contaminants | $357,410 | - | - | - | - |
$296
-
Tgal
|
$357,000 |
$114
-
Tgal
|
|
TOTAL RECOMMENDED | $574,754 | $84,470 |
$135,061
2,381,242
kWh
|
$16,630
-
kW-mo/yr
|
$56,347
-
MMBtu
|
$7,249
-
Tgal
|
$359,353 |
$114
-
Tgal
|
||
TOTAL IMPLEMENTED | $145,219 | $84,470 |
$77,002
1,360,027
kWh
|
$10,410
-
kW-mo/yr
|
$56,347
-
MMBtu
|
- | $1,460 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Administrative Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs