Assessment Year | 2014 |
---|---|
Principal Product | HVAC for automotive |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 290 |
Plant Area |
130,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 6,664
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $382,646 | 7,316,358 |
kWh
|
$0.052 |
Electricity Demand | $150,490 | 15,732 |
kW-mo/yr
|
$9.57 |
Natural Gas | $26,827 | 4,935 |
MMBtu
|
$5.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $157,495 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $10,884 | - |
$8,290
158,506
kWh
|
$2,063
-
kW-mo/yr
|
- | $531 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $724 | $1,400 |
$434
8,308
kWh
|
$108
-
kW-mo/yr
|
- | $182 | |
03 | 2.2511: Insulate bare equipment | $5,893 | $1,130 |
$4,719
90,228
kWh
|
$1,174
-
kW-mo/yr
|
- | - | |
04 | 2.6231: Utilize controls to operate equipment only when needed | $35,294 | $20,000 |
$33,546
641,415
kWh
|
$1,748
-
kW-mo/yr
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $867 | $1,000 |
$1,367
26,140
kWh
|
$340
-
kW-mo/yr
|
$(-840.0) | - | |
06 | 2.4322: Use or replace with energy efficient substitutes | $2,884 | $11,400 |
$2,309
44,150
kWh
|
$575
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $1,602 | - |
$1,283
24,529
kWh
|
$319
-
kW-mo/yr
|
- | - | |
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,794 | $8,675 |
$7,842
149,950
kWh
|
$1,952
-
kW-mo/yr
|
- | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,329 | $10,250 |
$3,466
66,276
kWh
|
$863
-
kW-mo/yr
|
- | - | |
10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,833 | $5,300 |
$1,833
35,041
kWh
|
- | - | - | |
11 | 2.6212: Turn off equipment during breaks, reduce operating time | $47,606 | - |
$47,606
1,041,414
kWh
|
- | - | - | |
12 | 2.4131: Size electric motors for peak operating efficiency | $35,785 | $199,800 |
$26,988
516,017
kWh
|
$8,797
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $157,495 | $258,955 |
$139,683
2,801,974
kWh
|
$17,939
-
kW-mo/yr
|
$(-840.0) | $713 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs