| Assessment Year | 2013 |
|---|---|
| Principal Product | Intermediate Bulk Containers |
| NAICS | 326160: Plastics Bottle Manufacturing |
| SIC | 3085: Plastics Bottles |
| Sales Range | $50 M to 100M |
| # of Employees | 80 |
| Plant Area |
120,000
ft2
|
| Annual Production | 480,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $806,672 | 11,342,400 |
kWh
|
$0.071 |
| Electricity Demand | $96,378 | 19,392 |
kW-mo/yr
|
$4.97 |
| Natural Gas | $19,391 | 2,680 |
MMBtu
|
$7.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $113,614 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $93,555 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $400 | $1,090 |
$400
5,624
kWh
|
- | - | - | |
| 02 | 2.7135: Install occupancy sensors | $6,740 | $6,852 |
$6,352
89,310
kWh
|
- | - | $388 | |
| 03 | 2.7124: Make a practice of turning off lights when not needed | $562 | - |
$542
7,625
kWh
|
- | - | $20 | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $31,028 | - |
$28,317
398,154
kWh
|
$2,711
-
kW-mo/yr
|
- | - | |
| 05 | 2.6218: Turn off equipment when not in use | $49,827 | - |
$49,827
700,602
kWh
|
- | - | - | |
| 06 | 2.4113: Install motor voltage controller on lightly loaded motors | $3,311 | $3,800 |
$3,311
46,549
kWh
|
- | - | - | |
| 07 | 2.2437: Recover waste heat from equipment | $14,202 | $1,200 |
$(-121.0)
(-1,702)
kWh
|
$(-12.0)
-
kW-mo/yr
|
$14,335
-
MMBtu
|
- | |
| 08 | 2.4224: Upgrade controls on compressors | $4,998 | - |
$4,508
63,381
kWh
|
$490
-
kW-mo/yr
|
- | - | |
| 09 | 2.2515: Use optimum thickness insulation | $2,546 | $314 |
$2,284
32,120
kWh
|
$262
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $113,614 | $13,256 |
$95,420
1,341,663
kWh
|
$3,451
-
kW-mo/yr
|
$14,335
-
MMBtu
|
$408 | ||
| TOTAL IMPLEMENTED | $93,555 | $7,942 |
$89,946
1,264,696
kWh
|
$3,201
-
kW-mo/yr
|
- | $408 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs