Assessment Year 2010
Principal Product Sheetmetal fabrication of vent, smoke, and fire damper units
NAICS 332322: Sheet Metal Work Manufacturing
SIC 3444: Sheet Metal Work
Sales Range $10
M
to 50
M
# of Employees 105
Plant Area 85,000
ft2
Annual Production 15,000
pieces
Production Hrs. Annual 2,000
hrs
Location (State) Kentucky

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $28,029 828,140
kWh
Electricity Demand $41,317 3,516
kW-mo/yr
Natural Gas $73,237 5,236
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,669 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,592

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.7135: Install occupancy sensors $207 $585 $207
5,225
kWh
- - -
02 2.4131: Size electric motors for peak operating efficiency $5,123 $58,000 $5,123
129,496
kWh
- - -
03 2.6218: Turn off equipment when not in use $2,804 $5,800 $2,804
70,870
kWh
- - -
04 2.4239: Eliminate or reduce compressed air usage $3,258 $800 $849
21,450
kWh
$2,409
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $995 $500 $620
15,664
kWh
$1,000
-
kW-mo/yr
- $(-625.0)
06 2.7447: Install vinyl strip / high speed / air curtain doors $15,685 $48,000 - - $15,685
-
MMBtu
-
07 2.7444: Close holes and openings in building such as broken windows $597 $50 - - $647
-
MMBtu
$(-50.0)
TOTAL RECOMMENDED $28,669 $113,735 $9,603
242,705
kWh
$3,409
-
kW-mo/yr
$16,332
-
MMBtu
$(-675.0)
TOTAL IMPLEMENTED $1,592 $550 $620
15,664
kWh
$1,000
-
kW-mo/yr
$647
-
MMBtu
$(-675.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs