| Assessment Year | 2010 |
|---|---|
| Principal Product | Sheetmetal fabrication of vent, smoke, and fire damper units |
| NAICS | 332322: Sheet Metal Work Manufacturing |
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 105 |
| Plant Area |
85,000
ft2
|
| Annual Production | 15,000
pieces
|
| Production Hrs. Annual | 2,000
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $28,029 | 828,140 |
kWh
|
$0.034 |
| Electricity Demand | $41,317 | 3,516 |
kW-mo/yr
|
$11.75 |
| Natural Gas | $73,237 | 5,236 |
MMBtu
|
$13.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,669 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,592 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $207 | $585 |
$207
5,225
kWh
|
- | - | - | |
| 02 | 2.4131: Size electric motors for peak operating efficiency | $5,123 | $58,000 |
$5,123
129,496
kWh
|
- | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $2,804 | $5,800 |
$2,804
70,870
kWh
|
- | - | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $3,258 | $800 |
$849
21,450
kWh
|
$2,409
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $995 | $500 |
$620
15,664
kWh
|
$1,000
-
kW-mo/yr
|
- | $(-625.0) | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $15,685 | $48,000 | - | - |
$15,685
-
MMBtu
|
- | |
| 07 | 2.7444: Close holes and openings in building such as broken windows | $597 | $50 | - | - |
$647
-
MMBtu
|
$(-50.0) | |
| TOTAL RECOMMENDED | $28,669 | $113,735 |
$9,603
242,705
kWh
|
$3,409
-
kW-mo/yr
|
$16,332
-
MMBtu
|
$(-675.0) | ||
| TOTAL IMPLEMENTED | $1,592 | $550 |
$620
15,664
kWh
|
$1,000
-
kW-mo/yr
|
$647
-
MMBtu
|
$(-675.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs