Assessment Year | 2011 |
---|---|
Principal Product | Canned Cat/Dog Food |
NAICS | 311111: Dog and Cat Food Manufacturing |
SIC | 2047: Dog and Cat Food |
Sales Range | $50 M to 100M |
# of Employees | 57 |
Plant Area |
186,000
ft2
|
Annual Production | 65,000,000
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $545,259 | 5,149,664 |
kWh
|
$0.11 |
Electricity Demand | $250,846 | 18,103 |
kW-mo/yr
|
$13.86 |
Natural Gas | $569,098 | 81,829 |
MMBtu
|
$6.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $146,815 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,983 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|
01 | 3.4151: Minimize water usage | $66,284 | $168,000 | - | - |
$66,284
-
Tgal
|
|
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $30,212 | $5,424 |
$25,389
239,524
kWh
|
$4,823
-
kW-mo/yr
|
- | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $22,751 | $160 |
$18,219
171,875
kWh
|
$4,532
-
kW-mo/yr
|
- | |
04 | 2.1212: Operate boilers on high fire setting | $16,771 | - |
$16,771
158,215
kWh
|
- | - | |
05 | 3.4155: Meter waste water | $10,797 | $3,240 |
$10,797
101,774
kWh
|
- | - | |
TOTAL RECOMMENDED | $146,815 | $176,824 |
$71,176
671,388
kWh
|
$9,355
-
kW-mo/yr
|
$66,284
-
Tgal
|
||
TOTAL IMPLEMENTED | $46,983 | $5,424 |
$42,160
397,739
kWh
|
$4,823
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs