Assessment Year | 2010 |
---|---|
Principal Product | Sinter-forged automotive transmission components |
NAICS | 332111: Iron and Steel Forging |
SIC | 3462: Iron and Steel Forgings |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
175,000
ft2
|
Annual Production | 8,000,000
pieces
|
Production Hrs. Annual | 5,880
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,502,358 | 23,270,400 |
kWh
|
$0.065 |
Natural Gas | $501,074 | 43,925 |
MMBtu
|
$11.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $309,870 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $145,245 | $145,245 | - | - | $145,245 | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,721 | $20 |
$1,654
36,750
kWh
|
$1,067
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $41,439 | $30,037 |
$25,038
556,401
kWh
|
$16,147
-
kW-mo/yr
|
- | - | $254 | |
04 | 2.4321: Upgrade obsolete equipment | $17,115 | $25,500 |
$17,115
380,328
kWh
|
- | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,928 | $500 |
$8,534
189,654
kWh
|
$3,694
-
kW-mo/yr
|
- | - | $(-1,300.0) | |
06 | 3.4116: Meter recycled water (to reduce sewer charges) | $5,479 | $1,000 | - | - | - | - | $5,479 | |
07 | 2.2515: Use optimum thickness insulation | $33,608 | $35,440 |
$23,011
511,356
kWh
|
$10,597
-
kW-mo/yr
|
- | - | - | |
08 | 2.4322: Use or replace with energy efficient substitutes | $22,346 | $44,693 | - | - | - |
$22,346
-
MMBtu
|
- | |
09 | 2.2424: Use heat in flue gases to preheat products or materials | $11,925 | $7,032 |
$7,250
161,112
kWh
|
$4,675
-
kW-mo/yr
|
- | - | - | |
10 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $6,484 | $6,000 |
$3,942
87,597
kWh
|
$2,542
-
kW-mo/yr
|
- | - | - | |
11 | 2.2211: Use optimum temperature | $3,080 | $6,160 |
$3,080
68,448
kWh
|
- | - | - | - | |
12 | 2.2211: Use optimum temperature | $492 | $25 |
$692
15,373
kWh
|
- | - | - | $(-200.0) | |
13 | 2.7241: Install outside air damper / economizer on hvac unit | $9,008 | $6,000 |
$9,008
200,178
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $309,870 | $307,652 |
$99,324
2,207,197
kWh
|
$38,722
-
kW-mo/yr
|
$145,245 |
$22,346
-
MMBtu
|
$4,233 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs