Assessment Year | 2010 |
---|---|
Principal Product | Aluminum, stainless and carbon slit coils and sheets |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
Sales Range | $50 M to 100M |
# of Employees | 50 |
Plant Area |
180,000
ft2
|
Annual Production | 70,000
ton
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,194 | 1,358,776 |
kWh
|
$0.058 |
Electricity Demand | $89,961 | 491 |
kW-mo/yr
|
$183.22 |
Natural Gas | $44,936 | 3,856 |
MMBtu
|
$11.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $48,361 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $27,175 | - | - | - | $27,175 | - | |
02 | 2.7444: Close holes and openings in building such as broken windows | $7,064 | $13,132 | - | - | - |
$7,064
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $897 | $1,000 |
$640
10,666
kWh
|
$257
-
kW-mo/yr
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $646 | - |
$461
7,684
kWh
|
$185
-
kW-mo/yr
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,579 | $50,000 |
$4,680
78,000
kWh
|
$7,899
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $48,361 | $64,132 |
$5,781
96,350
kWh
|
$8,341
-
kW-mo/yr
|
$27,175 |
$7,064
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs