Assessment Year | 2007 |
---|---|
Principal Product | Various Composite Products |
NAICS | 339999: All Other Miscellaneous Manufacturing |
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 108 |
Plant Area |
200,000
ft2
|
Annual Production | 7,000
pieces
|
Production Hrs. Annual | 3,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $319,500 | 3,820,973 |
kWh
|
$0.084 |
Natural Gas | $86,105 | 7,126 |
MMBtu
|
$12.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $65,353 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,040 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,680 | $80,800 |
$6,509
216,960
kWh
|
$12,267
-
kW-mo/yr
|
- | $904 | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,440 | $46,362 |
$11,440
381,327
kWh
|
- | - | - | - | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $10,780 | $20,512 |
$450
14,984
kWh
|
- |
$10,330
-
MMBtu
|
- | - | |
04 | 2.7132: Install timers on light switches in little used areas | $8,081 | $4,600 |
$1,656
55,200
kWh
|
$6,425
-
kW-mo/yr
|
- | - | - | |
05 | 2.1224: Replace boiler | $5,791 | $40,000 | - | - |
$5,791
-
MMBtu
|
- | - | |
06 | 2.6218: Turn off equipment when not in use | $5,131 | $1,000 | - | - | - | - |
$5,131
-
Tgal
|
|
07 | 2.4224: Upgrade controls on compressors | $2,180 | - |
$2,180
72,677
kWh
|
- | - | - | - | |
08 | 2.7261: Install timers and/or thermostats | $1,410 | $400 |
$565
18,833
kWh
|
- |
$845
-
MMBtu
|
- | - | |
09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $860 | - | - | - |
$860
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $65,353 | $193,674 |
$22,800
759,981
kWh
|
$18,692
-
kW-mo/yr
|
$17,826
-
MMBtu
|
$904 |
$5,131
-
Tgal
|
||
TOTAL IMPLEMENTED | $3,040 | - |
$2,180
72,677
kWh
|
- |
$860
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs