| Assessment Year | 2007 |
|---|---|
| Principal Product | Farm Machinery |
| NAICS | 333111: Farm Machinery and Equipment Manufacturing |
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $1 M to 5M |
| # of Employees | 25 |
| Plant Area |
35,000
ft2
|
| Annual Production | 250,000
units
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $27,727 | 168,440 |
kWh
|
$0.16 |
| Natural Gas | $19,944 | 1,756 |
MMBtu
|
$11.36 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,338 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,712 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $9,128 | $3,450 | - | - |
$9,128
-
MMBtu
|
- | |
| 02 | 2.9111: Use solar heat to heat make-up air | $4,626 | $17,500 | - | - |
$4,626
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,922 | $7,945 |
$948
20,617
kWh
|
$1,905
-
kW-mo/yr
|
- | $69 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,808 | $3,777 |
$829
18,023
kWh
|
$1,666
-
kW-mo/yr
|
- | $313 | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,628 | $915 |
$497
10,800
kWh
|
$1,131
-
kW-mo/yr
|
- | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $997 | - |
$666
7,191
kWh
|
$331
-
kW-mo/yr
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $764 | $883 |
$340
7,410
kWh
|
$424
-
kW-mo/yr
|
- | - | |
| 08 | 2.7145: Install skylights | $666 | $2,421 |
$666
14,477
kWh
|
- | - | - | |
| 09 | 2.7311: Ventilation system to shut off when room is not in use | $500 | - | - | - |
$500
-
MMBtu
|
- | |
| 10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $496 | - |
$25
542
kWh
|
$471
-
kW-mo/yr
|
- | - | |
| 11 | 2.7145: Install skylights | $354 | $1,083 |
$354
7,692
kWh
|
- | - | - | |
| 12 | 2.4221: Install compressor air intakes in coolest locations | $233 | $500 |
$77
1,683
kWh
|
$156
-
kW-mo/yr
|
- | - | |
| 13 | 2.4221: Install compressor air intakes in coolest locations | $216 | $324 |
$72
1,566
kWh
|
$144
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $25,338 | $38,798 |
$4,474
90,001
kWh
|
$6,228
-
kW-mo/yr
|
$14,254
-
MMBtu
|
$382 | ||
| TOTAL IMPLEMENTED | $20,712 | $21,298 |
$4,474
90,001
kWh
|
$6,228
-
kW-mo/yr
|
$9,628
-
MMBtu
|
$382 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs