Assessment Year | 2005 |
---|---|
Principal Product | Laminated Sheets and Fabricated Products |
NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
SIC | 3260: |
Sales Range | $10 M to 50M |
# of Employees | 73 |
Plant Area |
130,000
ft2
|
Annual Production | 3,800,000
lb
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $120,482 | 1,738,236 |
kWh
|
$0.069 |
Electricity Demand | $83,054 | 7,020 |
kW-mo/yr
|
$11.83 |
Natural Gas | $27,020 | 3,207 |
MMBtu
|
$8.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $104,073 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,011 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3137: Use power during off-peak periods | $53,783 | - | - |
$53,783
-
kW-mo/yr
|
- | - | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $11,962 | - |
$3,740
68,000
kWh
|
$3,038
-
kW-mo/yr
|
$5,184
-
MMBtu
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,895 | $41,280 |
$4,740
86,190
kWh
|
$6,946
-
kW-mo/yr
|
- |
$209
-
lb
|
|
04 | 2.4224: Upgrade controls on compressors | $8,639 | $2,100 |
$2,922
70,720
kWh
|
$5,717
-
kW-mo/yr
|
- | - | |
05 | 2.5123: Reduce fluid flow rates | $6,270 | $22,000 |
$1,519
27,625
kWh
|
$2,323
-
kW-mo/yr
|
$2,428
-
MMBtu
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $3,243 | $1,080 |
$1,313
23,868
kWh
|
$1,930
-
kW-mo/yr
|
- | - | |
07 | 2.5123: Reduce fluid flow rates | $3,226 | - |
$316
5,738
kWh
|
$482
-
kW-mo/yr
|
$2,428
-
MMBtu
|
- | |
08 | 2.7135: Install occupancy sensors | $2,677 | $1,600 |
$2,677
48,672
kWh
|
- | - | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,237 | - |
$486
8,840
kWh
|
$751
-
kW-mo/yr
|
- | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $1,141 | $2,500 |
$462
8,398
kWh
|
$679
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $104,073 | $70,560 |
$18,175
348,051
kWh
|
$75,649
-
kW-mo/yr
|
$10,040
-
MMBtu
|
$209
-
lb
|
||
TOTAL IMPLEMENTED | $34,011 | $25,700 |
$11,660
229,595
kWh
|
$12,311
-
kW-mo/yr
|
$10,040
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs