Assessment Year | 2002 |
---|---|
Principal Product | Robotic welded parts |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 425 |
Plant Area |
140,000
ft2
|
Annual Production | 14,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,276 | 2,757,194 |
kWh
|
$0.029 |
Electricity Demand | $165,015 | 10,416 |
kW-mo/yr
|
$15.84 |
Natural Gas | $24,200 | 2,649 |
MMBtu
|
$9.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $231,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $37,491 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.425: Eliminate/reduce redundant inspections | $160,000 | - | - | - | $160,000 | - | |
02 | 4.311: Schedule deliveries according to demand | $36,000 | - | - | - | - | $36,000 | |
03 | 4.514: Re-arrange equipment layout to reduce handling costs | $24,000 | $2,500 | - | - | $24,000 | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,934 | $1,390 |
$1,764
63,000
kWh
|
$2,170
-
kW-mo/yr
|
- | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $3,677 | $1,680 |
$1,310
46,800
kWh
|
$2,367
-
kW-mo/yr
|
- | - | |
06 | 2.7122: Disconnect ballasts | $2,338 | $110 |
$1,075
38,400
kWh
|
$1,263
-
kW-mo/yr
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,266 | $3,422 |
$280
10,000
kWh
|
$986
-
kW-mo/yr
|
- | - | |
08 | 2.7124: Make a practice of turning off lights when not needed | $225 | $80 |
$126
4,500
kWh
|
$99
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $231,440 | $9,182 |
$4,555
162,700
kWh
|
$6,885
-
kW-mo/yr
|
$184,000 | $36,000 | ||
TOTAL IMPLEMENTED | $37,491 | $3,502 |
$406
14,500
kWh
|
$1,085
-
kW-mo/yr
|
- | $36,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs