Assessment Year | 2002 |
---|---|
Principal Product | Ready-to-assemble furniture |
NAICS |
n/a
|
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 500 |
Plant Area |
500,000
ft2
|
Annual Production | 2,500,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $261,492 | 11,886,000 |
kWh
|
$0.022 |
Electricity Demand | $310,128 | 27,108 |
kW-mo/yr
|
$11.44 |
Natural Gas | $60,500 | 11,000 |
MMBtu
|
$5.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $50,947 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,698 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,980 | $62,617 |
$8,052
366,000
kWh
|
$7,928
-
kW-mo/yr
|
- | |
02 | 2.7225: Close outdoor air dampers during warm-up / cool-down periods | $8,910 | - | - | - |
$8,910
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $8,519 | $19,155 |
$3,451
156,878
kWh
|
$5,068
-
kW-mo/yr
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $5,035 | $8,000 |
$2,033
92,400
kWh
|
$3,002
-
kW-mo/yr
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,715 | $11,637 |
$2,376
108,000
kWh
|
$2,339
-
kW-mo/yr
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,799 | $2,324 |
$1,590
72,250
kWh
|
$2,209
-
kW-mo/yr
|
- | |
07 | 2.2437: Recover waste heat from equipment | $2,899 | - | - | - |
$2,899
-
MMBtu
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $1,090 | $400 |
$440
20,000
kWh
|
$650
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $50,947 | $104,133 |
$17,942
815,528
kWh
|
$21,196
-
kW-mo/yr
|
$11,809
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,698 | $2,724 |
$2,030
92,250
kWh
|
$2,859
-
kW-mo/yr
|
$11,809
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs