Assessment Year | 2002 |
---|---|
Principal Product | Adhesive application equipment |
NAICS |
n/a
|
SIC | 3332: |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
77,338
ft2
|
Annual Production | 639
pieces
|
Production Hrs. Annual | 5,720
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,935 | 966,720 |
kWh
|
$0.032 |
Electricity Demand | $46,345 | 4,128 |
kW-mo/yr
|
$11.23 |
Natural Gas | $18,606 | 2,041 |
MMBtu
|
$9.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,948 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,892 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,187 | $8,190 |
$1,298
40,560
kWh
|
$1,889
-
kW-mo/yr
|
- | - | - | |
02 | 3.5112: Reprocess spent oils on site for re-use | $3,149 | $3,200 | - | - | - |
$3,149
-
gal
|
- | |
03 | 2.4226: Use / purchase optimum sized compressor | $3,139 | $9,000 |
$(-1,006.0)
(-31,460)
kWh
|
$(-799.0)
-
kW-mo/yr
|
- | - | $4,944 | |
04 | 2.7122: Disconnect ballasts | $549 | - |
$549
17,160
kWh
|
- | - | - | - | |
05 | 2.2437: Recover waste heat from equipment | $507 | - | - | - |
$507
-
MMBtu
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $230 | - |
$128
4,004
kWh
|
$102
-
kW-mo/yr
|
- | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $132 | $150 |
$74
2,288
kWh
|
$58
-
kW-mo/yr
|
- | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $55 | $12 |
$55
1,716
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $10,948 | $20,552 |
$1,098
34,268
kWh
|
$1,250
-
kW-mo/yr
|
$507
-
MMBtu
|
$3,149
-
gal
|
$4,944 | ||
TOTAL IMPLEMENTED | $9,892 | $20,552 |
$549
17,108
kWh
|
$1,250
-
kW-mo/yr
|
- |
$3,149
-
gal
|
$4,944 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs