| Assessment Year | 1998 |
|---|---|
| Principal Product | Fuel and oil filters |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $100 M to 500M |
| # of Employees | 1,100 |
| Plant Area |
300,000
ft2
|
| Annual Production | 18,000,000
lb
|
| Production Hrs. Annual | 5,800
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $621,671 | 23,917,351 |
kWh
|
$0.026 |
| Electricity Demand | $838,122 | 59,568 |
kW-mo/yr
|
$14.07 |
| Natural Gas | $354,676 | 83,991 |
MMBtu
|
$4.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $616,399 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $464,698 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $228,030 | $30,000 | - | - | $900 | - | $330 | - | - | $226,800 | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $143,713 | $70,000 |
$50,663
2,484,174
kWh
|
$93,050
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 03 | 4.652: Replace existing equipment with more suitable substitutes | $181,440 | $75,000 | - | - | - | - | $181,440 | - | - | - | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $19,335 | $28,000 |
$6,549
321,219
kWh
|
$10,369
-
kW-mo/yr
|
- | - | - | $2,417 | - | - | |
| 05 | 3.5146: Utilize a central coolant system for cleaning and reuse of metal working fluid | $7,988 | $11,200 | - | - | - |
$1,177
-
gal
|
- | - | $6,811 | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,918 | - |
$3,252
159,437
kWh
|
$4,666
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,126 | $57,752 |
$7,286
357,268
kWh
|
$8,840
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $11,849 | $500 |
$5,324
261,137
kWh
|
$6,525
-
kW-mo/yr
|
- | - | - | - | - | - | |
| TOTAL RECOMMENDED | $616,399 | $272,452 |
$73,074
3,583,235
kWh
|
$123,450
-
kW-mo/yr
|
$900 |
$1,177
-
gal
|
$181,770 | $2,417 | $6,811 | $226,800 | ||
| TOTAL IMPLEMENTED | $464,698 | $191,252 |
$22,411
1,099,061
kWh
|
$30,400
-
kW-mo/yr
|
$900 | - | $181,770 | $2,417 | - | $226,800 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Other Liquid (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs