Assessment Year | 1997 |
---|---|
Principal Product | Lubricants Oils, Calcium Oxide |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $5 M to 10M |
# of Employees | 42 |
Plant Area |
40,000
ft2
|
Annual Production | 13,000,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $19,302 | 438,746 |
kWh
|
$0.044 |
Electricity Demand | $15,774 | 2,868 |
kW-mo/yr
|
$5.50 |
Natural Gas | $12,801 | 2,616 |
MMBtu
|
$4.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,136 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $42,437 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.6212: Turn off equipment during breaks, reduce operating time | $508 | - |
$508
11,430
kWh
|
- | - | - | - | - | |
02 | 2.3191: Use demand controller or load shedder | $2,468 | $200 | - |
$2,468
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,455 | $2,564 |
$1,188
26,964
kWh
|
$267
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown | $352 | $50 |
$201
4,689
kWh
|
$151
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4224: Upgrade controls on compressors | $553 | $750 |
$264
5,862
kWh
|
- |
$289
-
MMBtu
|
- | - | - | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $1,574 | $20,000 |
$2,636
59,789
kWh
|
$469
-
kW-mo/yr
|
$(-1,531.0)
-
MMBtu
|
- | - | - | |
07 | 4.652: Replace existing equipment with more suitable substitutes | $37,000 | $36,000 | - | - | - | - | $35,000 | $2,000 | |
08 | 2.6212: Turn off equipment during breaks, reduce operating time | $101 | $50 |
$58
1,172
kWh
|
$43
-
kW-mo/yr
|
- | - | - | - | |
09 | 3.4151: Minimize water usage | $125 | $60 | - | - |
$35
-
MMBtu
|
$90
-
lb
|
- | - | |
TOTAL RECOMMENDED | $44,136 | $59,674 |
$4,855
109,906
kWh
|
$3,398
-
kW-mo/yr
|
$(-1,207.0)
-
MMBtu
|
$90
-
lb
|
$35,000 | $2,000 | ||
TOTAL IMPLEMENTED | $42,437 | $39,614 |
$2,219
50,117
kWh
|
$2,929
-
kW-mo/yr
|
$289
-
MMBtu
|
- | $35,000 | $2,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (haz) Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs