Assessment Year | 1995 |
---|---|
Principal Product | pressure sensitive labels, coating for packaging |
NAICS |
n/a
|
SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
70,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 7,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $248,074 | 4,342,907 |
kWh
|
$0.057 |
Natural Gas | $23,310 | 5,011 |
MMBtu
|
$4.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,340 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4226: Use / purchase optimum sized compressor | $493 | - |
$493
23,740
kWh
|
- | - | |
02 | 2.3191: Use demand controller or load shedder | $4,512 | $12,000 |
$4,512
-
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,335 | $16,387 |
$14,365
252,052
kWh
|
$(-1,755.0)
-
MMBtu
|
$725 | |
TOTAL RECOMMENDED | $18,340 | $28,387 |
$19,370
275,792
kWh
|
$(-1,755.0)
-
MMBtu
|
$725 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs