Assessment Year | 1994 |
---|---|
Principal Product | glass bottles |
NAICS |
n/a
|
SIC | 3221: Glass Containers |
Sales Range | $50 M to 100M |
# of Employees | 300 |
Plant Area |
504,100
ft2
|
Annual Production | 100,000
ton
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,159,600 | 29,676,437 |
kWh
|
$0.039 |
Natural Gas | $1,443,800 | 525,000 |
MMBtu
|
$2.75 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $113,421 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $56,512 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $46,224 | $42,000 |
$46,224
-
kWh
|
- | |
02 | 2.7314: Reduce ventilation air | $5,261 | $4,000 |
$5,261
134,525
kWh
|
- | |
03 | 2.4226: Use / purchase optimum sized compressor | $56,909 | $35,000 |
$54,909
1,403,283
kWh
|
$2,000 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,027 | $2,280 |
$2,057
53,341
kWh
|
$2,970 | |
TOTAL RECOMMENDED | $113,421 | $83,280 |
$108,451
1,591,149
kWh
|
$4,970 | ||
TOTAL IMPLEMENTED | $56,512 | $48,280 |
$53,542
187,866
kWh
|
$2,970 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs