| Assessment Year | 1994 |
|---|---|
| Principal Product | fluid dairy and juice products |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $50 M to 100M |
| # of Employees | 85 |
| Plant Area |
30,000
ft2
|
| Annual Production | 31,000
Tgal
|
| Production Hrs. Annual | 7,500
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $351,385 | 6,549,531 |
kWh
|
$0.054 |
| Natural Gas | $73,778 | 13,588 |
MMBtu
|
$5.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,923 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $38,923 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $4,831 | $8,000 |
$4,831
-
kWh
|
- | - | |
| 02 | 3.4114: Replace city water with recycled water via cooling tower | $14,462 | $7,500 |
$(-1,765.0)
(-29,894)
kWh
|
$(-500.0) |
$16,727
-
Tgal
|
|
| 03 | 2.3137: Use power during off-peak periods | $13,081 | - |
$13,081
-
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,504 | $12,960 |
$4,504
70,633
kWh
|
- | - | |
| 05 | 2.6231: Utilize controls to operate equipment only when needed | $2,045 | $300 |
$2,045
96,424
kWh
|
- | - | |
| TOTAL RECOMMENDED | $38,923 | $28,760 |
$22,696
137,163
kWh
|
$(-500.0) |
$16,727
-
Tgal
|
||
| TOTAL IMPLEMENTED | $38,923 | $28,760 |
$22,696
137,163
kWh
|
$(-500.0) |
$16,727
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs