| Assessment Year | 1993 |
|---|---|
| Principal Product | aerospace composite hardware |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 130 |
| Plant Area |
92,500
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $107,345 | 1,943,728 |
kWh
|
$0.055 |
| Natural Gas | $56,894 | 12,424 |
MMBtu
|
$4.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,745 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,745 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.8112: Combine utility meters | $838 | $200 | - |
$838
-
MMBtu
|
|
| 02 | 2.4226: Use / purchase optimum sized compressor | $4,462 | $100 |
$4,462
208,675
kWh
|
- | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $445 | $20 |
$549
11,723
kWh
|
$(-104.0)
-
MMBtu
|
|
| TOTAL RECOMMENDED | $5,745 | $320 |
$5,011
220,398
kWh
|
$734
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,745 | $320 |
$5,011
220,398
kWh
|
$734
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs