| Assessment Year | 1993 |
|---|---|
| Principal Product | blades, vanes, blisks, vane disk |
| NAICS |
n/a
|
| SIC | 3544: Special Dies and Tools, Die Sets, Jigs and Fixtures, and Industrial Molds |
| Sales Range | $10 M to 50M |
| # of Employees | 153 |
| Plant Area |
30,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $490,555 | 9,781,653 |
kWh
|
$0.050 |
| Natural Gas | $8,185 | 1,839 |
MMBtu
|
$4.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $21,768 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,744 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $15,566 | - |
$15,566
-
kWh
|
|
| 02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,952 | - |
$2,952
-
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,178 | $2,100 |
$1,178
22,860
kWh
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $1,637 | $400 |
$1,637
39,859
kWh
|
|
| 05 | 2.7261: Install timers and/or thermostats | $435 | $600 |
$435
20,223
kWh
|
|
| TOTAL RECOMMENDED | $21,768 | $3,100 |
$21,768
82,942
kWh
|
||
| TOTAL IMPLEMENTED | $16,744 | $2,100 |
$16,744
22,860
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs