| Assessment Year | 1992 |
|---|---|
| Principal Product | FRACTIONAL H.P. MOTORS |
| NAICS |
n/a
|
| SIC | 3621: Motors and Generators |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 1,900,000
pieces
|
| Production Hrs. Annual | 3,500
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $271,923 | 4,761,430 |
kWh
|
$0.057 |
| Natural Gas | $13,646 | 3,686 |
MMBtu
|
$3.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,277 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,114 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6232: Install set-back timers | $23,156 | - |
$23,156
430,246
kWh
|
|
| 02 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $1,650 | - |
$1,650
19,050
kWh
|
|
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,357 | - |
$6,357
-
kWh
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $13,114 | $14,400 |
$13,114
194,900
kWh
|
|
| TOTAL RECOMMENDED | $44,277 | $14,400 |
$44,277
644,196
kWh
|
||
| TOTAL IMPLEMENTED | $13,114 | $14,400 |
$13,114
194,900
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs