Assessment Year | 1992 |
---|---|
Principal Product | ALUMINUM CASTINGS |
NAICS |
n/a
|
SIC | 3363: Aluminum Die-Castings |
Sales Range | $10 M to 50M |
# of Employees | 188 |
Plant Area |
n/a
|
Annual Production | 12,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $717,148 | 12,158,851 |
kWh
|
$0.059 |
Natural Gas | $124,294 | 38,992 |
MMBtu
|
$3.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,263 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,121 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $8,100 | $20,000 |
$8,100
-
kWh
|
- | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $9,728 | $3,200 |
$9,728
360,492
kWh
|
- | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $18,314 | $90,000 |
$36,222
612,251
kWh
|
$(-17,908.0)
-
MMBtu
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,121 | $14,430 |
$8,121
150,059
kWh
|
- | |
TOTAL RECOMMENDED | $44,263 | $127,630 |
$62,171
1,122,802
kWh
|
$(-17,908.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,121 | $14,430 |
$8,121
150,059
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs