Assessment Year | 1991 |
---|---|
Principal Product | ELECTRIC WELDED TUBING |
NAICS |
n/a
|
SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
Sales Range | $50 M to 100M |
# of Employees | 390 |
Plant Area |
n/a
|
Annual Production | 120
thousand feet
|
Production Hrs. Annual | 5,800
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $536,085 | 10,038,394 |
kWh
|
$0.053 |
Natural Gas | $313,886 | 80,012 |
MMBtu
|
$3.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $158,917 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3511: Use plant owned transformers or lease transformers | $69,034 | - |
$74,034
-
kWh
|
- | $(-5,000.0) | |
02 | 2.2491: Use cooling air which cools hot work pieces for space heating | $37,108 | $90,000 | - |
$37,108
-
MMBtu
|
- | |
03 | 2.2511: Insulate bare equipment | $3,239 | $2,700 | - |
$3,239
-
MMBtu
|
- | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $2,619 | - |
$2,980
64,185
kWh
|
$(-676.0)
-
MMBtu
|
$315 | |
05 | 2.6232: Install set-back timers | $1,077 | - |
$1,391
46,307
kWh
|
$(-489.0)
-
MMBtu
|
$175 | |
06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $45,840 | - |
$51,840
-
kWh
|
- | $(-6,000.0) | |
TOTAL RECOMMENDED | $158,917 | $92,700 |
$130,245
110,492
kWh
|
$39,182
-
MMBtu
|
$(-10,510.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs