Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $328,301 | 6,452,228 |
kWh
|
$0.051 |
Natural Gas | $59,146 | 12,790 |
MMBtu
|
$4.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,017 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7221: Lower temperature during the winter season and vice-versa | $1,879 | - |
$1,879
36,049
kWh
|
- | - | |
02 | 3.4115: Recover and reuse cooling water | $8,744 | $10,000 |
$474
9,672
kWh
|
- | $8,270 | |
03 | 2.2437: Recover waste heat from equipment | $8,017 | $15,000 | - |
$1,087
-
MMBtu
|
$6,930 | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $3,681 | $500 |
$3,758
75,909
kWh
|
$(-493.0)
-
MMBtu
|
$416 | |
05 | 2.6232: Install set-back timers | $5,716 | $1,500 |
$6,389
214,537
kWh
|
$(-1,393.0)
-
MMBtu
|
$720 | |
TOTAL RECOMMENDED | $28,037 | $27,000 |
$12,500
336,167
kWh
|
$(-799.0)
-
MMBtu
|
$16,336 | ||
TOTAL IMPLEMENTED | $8,017 | $15,000 | - |
$1,087
-
MMBtu
|
$6,930 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs