| Assessment Year | 1990 |
|---|---|
| Principal Product | AUTO PACKAGING MACHINES |
| NAICS |
n/a
|
| SIC | 3569: General Industrial Machinery and Equipment, Not Elsewhere |
| Sales Range | $50 M to 100M |
| # of Employees | 510 |
| Plant Area |
n/a
|
| Annual Production | 120
pieces
|
| Production Hrs. Annual | 5,000
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $328,301 | 6,452,228 |
kWh
|
$0.051 |
| Natural Gas | $59,146 | 12,790 |
MMBtu
|
$4.62 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,037 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,017 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7221: Lower temperature during the winter season and vice-versa | $1,879 | - |
$1,879
36,049
kWh
|
- | - | |
| 02 | 3.4115: Recover and reuse cooling water | $8,744 | $10,000 |
$474
9,672
kWh
|
- | $8,270 | |
| 03 | 2.2437: Recover waste heat from equipment | $8,017 | $15,000 | - |
$1,087
-
MMBtu
|
$6,930 | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $3,681 | $500 |
$3,758
75,909
kWh
|
$(-493.0)
-
MMBtu
|
$416 | |
| 05 | 2.6232: Install set-back timers | $5,716 | $1,500 |
$6,389
214,537
kWh
|
$(-1,393.0)
-
MMBtu
|
$720 | |
| TOTAL RECOMMENDED | $28,037 | $27,000 |
$12,500
336,167
kWh
|
$(-799.0)
-
MMBtu
|
$16,336 | ||
| TOTAL IMPLEMENTED | $8,017 | $15,000 | - |
$1,087
-
MMBtu
|
$6,930 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs