| Assessment Year | 1990 |
|---|---|
| Principal Product | PLASTIC AUTO COMPONENTS |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
n/a
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $321,275 | 6,712,485 |
kWh
|
$0.048 |
| Natural Gas | $28,694 | 6,134 |
MMBtu
|
$4.68 |
| Other Energy | $1,256 | 1,256 |
MMBtu
|
$1.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $33,238 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $33,238 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $17,856 | $20,000 |
$17,856
-
kWh
|
- | - | |
| 02 | 2.2437: Recover waste heat from equipment | $5,309 | $1,000 | - |
$5,309
-
MMBtu
|
- | |
| 03 | 3.6124: Burn waste oil for heat | $6,067 | - |
$263
4,396
kWh
|
$5,804
-
MMBtu
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,783 | $7,500 |
$2,393
60,375
kWh
|
- | $390 | |
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,223 | $6,240 | - |
$1,223
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $33,238 | $34,740 |
$20,512
64,771
kWh
|
$12,336
-
MMBtu
|
$390 | ||
| TOTAL IMPLEMENTED | $33,238 | $34,740 |
$20,512
64,771
kWh
|
$12,336
-
MMBtu
|
$390 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs