| Assessment Year | 1988 |
|---|---|
| Principal Product | AUTOMOTIVE EXHAUST PIPES |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $5 M to 10M |
| # of Employees | 65 |
| Plant Area |
n/a
|
| Annual Production | 600,000
pieces
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $105,219 | 1,228,019 |
kWh
|
$0.086 |
| Natural Gas | $25,609 | 6,059 |
MMBtu
|
$4.23 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $38,296 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $38,296 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7314: Reduce ventilation air | $8,923 | $500 | - |
$8,923
-
MMBtu
|
- | |
| 02 | 2.7261: Install timers and/or thermostats | $3,754 | $900 | - |
$3,754
-
MMBtu
|
- | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $11,724 | - |
$12,220
-
kWh
|
$(-150.0)
-
MMBtu
|
$(-346.0) | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,413 | $32,500 |
$15,093
193,142
kWh
|
$(-1,886.0)
-
MMBtu
|
$206 | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $482 | $650 |
$313
4,103
kWh
|
- | $169 | |
| TOTAL RECOMMENDED | $38,296 | $34,550 |
$27,626
197,245
kWh
|
$10,641
-
MMBtu
|
$29 | ||
| TOTAL IMPLEMENTED | $38,296 | $34,550 |
$27,626
197,245
kWh
|
$10,641
-
MMBtu
|
$29 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs