Assessment Year | 1988 |
---|---|
Principal Product | METAL STAMPINGS |
NAICS |
n/a
|
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
n/a
|
Annual Production | 8,000,000
lb
|
Production Hrs. Annual | 4,800
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $132,778 | 1,844,959 |
kWh
|
$0.072 |
Natural Gas | $27,262 | 6,007 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,112 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,518 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7442: Keep doors and windows shut when not on use | $4,647 | $500 |
$3,200
39,859
kWh
|
$1,447
-
MMBtu
|
- | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,125 | - |
$3,374
-
kWh
|
- | $(-249.0) | |
03 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $1,025 | $2,000 |
$1,025
12,896
kWh
|
- | - | |
04 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $1,447 | - | - |
$1,447
-
MMBtu
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $1,399 | $180 |
$1,448
19,930
kWh
|
$(-109.0)
-
MMBtu
|
$60 | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $2,469 | $200 |
$2,485
45,135
kWh
|
$(-241.0)
-
MMBtu
|
$225 | |
TOTAL RECOMMENDED | $14,112 | $2,880 |
$11,532
117,820
kWh
|
$2,544
-
MMBtu
|
$36 | ||
TOTAL IMPLEMENTED | $8,518 | $2,680 |
$5,673
72,685
kWh
|
$2,785
-
MMBtu
|
$60 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs