Assessment Year 2020
Principal Product Conveying equipment
NAICS 333922: Conveyor and Conveying Equipment Manufacturing
SIC 3535: Conveyors and Conveying Equipment
Sales Range $50
M
to 100
M
# of Employees 274
Plant Area 200,000
ft2
Annual Production 350
units
Production Hrs. Annual 2,600
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $102,549 1,825,355
kWh
Electricity Demand $97,480 6,910
kW-mo/yr
Electricity Fees $2,239 -
Natural Gas $39,463 8,397
MMBtu
Waste Disposal Costs
Water Usage $77,668 10,166
Tgal
TOTAL YEARLY COSTS $319,399
RECOMMENDED SAVINGS* $42,062 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,930

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $26,909 $49,013 $14,182
253,258
kWh
$12,727
-
kW-mo/yr
-
02 2.3212: Optimize plant power factor $8,582 $18,054 - - $8,582
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,014 $2,340 $2,014
35,961
kWh
- -
04 2.4221: Install compressor air intakes in coolest locations $536 $713 $395
7,061
kWh
$141
-
kW-mo/yr
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $459 $320 $459
8,199
kWh
- -
06 2.7224: Reduce space conditioning during non-working hours $1,799 - $1,799
32,123
kWh
- -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,763 $4,560 $1,763
31,488
kWh
- -
TOTAL RECOMMENDED $42,062 $75,000 $20,612
368,090
kWh
$12,868
-
kW-mo/yr
$8,582
TOTAL IMPLEMENTED $30,930 $53,893 $18,203
325,068
kWh
$12,727
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings