Assessment Year | 1983 |
---|---|
Principal Product | WOMEN'S SHOES |
NAICS |
n/a
|
SIC | 3144: Women's Footwear, Except Athletic |
Sales Range | $10 M to 50M |
# of Employees | 275 |
Plant Area |
n/a
|
Annual Production | 625,000
pieces
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $72,811 | 1,026,084 |
kWh
|
$0.071 |
Natural Gas | $58,087 | 9,985 |
MMBtu
|
$5.82 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,548 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,285 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.6242: Minimize operation of equipment maintained in standby condition | $3,030 | $1,000 |
$3,030
40,445
kWh
|
- | |
02 | 2.7494: Install storm windows and doors | $5,208 | $2,000 | - |
$5,208
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,279 | $4,668 |
$2,912
38,394
kWh
|
$(-633.0)
-
MMBtu
|
|
04 | 2.7261: Install timers and/or thermostats | $7,768 | $2,000 | - |
$7,768
-
MMBtu
|
|
05 | 2.2136: Install / repair insulation on steam lines | $263 | $1,590 | - |
$263
-
MMBtu
|
|
TOTAL RECOMMENDED | $18,548 | $11,258 |
$5,942
78,839
kWh
|
$12,606
-
MMBtu
|
||
TOTAL IMPLEMENTED | $18,285 | $9,668 |
$5,942
78,839
kWh
|
$12,343
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs