Assessment Year | 1983 |
---|---|
Principal Product | SECURITY WINDOWS |
NAICS |
n/a
|
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
n/a
|
Annual Production | 40
thousand feet
|
Production Hrs. Annual | 1,992
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $91,395 | 1,063,892 |
kWh
|
$0.086 |
Natural Gas | $123,787 | 23,607 |
MMBtu
|
$5.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,027 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,696 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.5195: Change product design to reduce energy requirements | $13,041 | $4,710 | - |
$13,041
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $11,682 | $4,000 | - |
$11,682
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,369 | $2,467 |
$4,864
46,893
kWh
|
$(-495.0)
-
MMBtu
|
|
04 | 2.1221: Replace obsolete burners with more efficient ones | $3,053 | $6,225 | - |
$3,053
-
MMBtu
|
|
05 | 2.7494: Install storm windows and doors | $1,186 | $2,252 | - |
$1,186
-
MMBtu
|
|
06 | 2.5194: Redesign process | $13,696 | $30,000 | - |
$13,696
-
MMBtu
|
|
TOTAL RECOMMENDED | $47,027 | $49,654 |
$4,864
46,893
kWh
|
$42,163
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,696 | $30,000 | - |
$13,696
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs