| Assessment Year | 1983 |
|---|---|
| Principal Product | SECURITY WINDOWS |
| NAICS |
n/a
|
| SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
| Sales Range | $10 M to 50M |
| # of Employees | 160 |
| Plant Area |
n/a
|
| Annual Production | 40
thousand feet
|
| Production Hrs. Annual | 1,992
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $91,395 | 1,063,892 |
kWh
|
$0.086 |
| Natural Gas | $123,787 | 23,607 |
MMBtu
|
$5.24 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $47,027 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,696 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.5195: Change product design to reduce energy requirements | $13,041 | $4,710 | - |
$13,041
-
MMBtu
|
|
| 02 | 2.7261: Install timers and/or thermostats | $11,682 | $4,000 | - |
$11,682
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,369 | $2,467 |
$4,864
46,893
kWh
|
$(-495.0)
-
MMBtu
|
|
| 04 | 2.1221: Replace obsolete burners with more efficient ones | $3,053 | $6,225 | - |
$3,053
-
MMBtu
|
|
| 05 | 2.7494: Install storm windows and doors | $1,186 | $2,252 | - |
$1,186
-
MMBtu
|
|
| 06 | 2.5194: Redesign process | $13,696 | $30,000 | - |
$13,696
-
MMBtu
|
|
| TOTAL RECOMMENDED | $47,027 | $49,654 |
$4,864
46,893
kWh
|
$42,163
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $13,696 | $30,000 | - |
$13,696
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs