Assessment Year | 1982 |
---|---|
Principal Product | CENTRIFUGAL PUMPS |
NAICS |
n/a
|
SIC | 3561: Pumps and Pumping Equipment |
Sales Range | $10 M to 50M |
# of Employees | 377 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 3,800
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $263,192 | 4,446,073 |
kWh
|
$0.059 |
Natural Gas | $80,252 | 18,098 |
MMBtu
|
$4.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $66,226 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $30,786 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,852 | $63,993 |
$18,328
325,322
kWh
|
$(-476.0)
-
MMBtu
|
|
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $17,588 | $2,222 |
$17,588
-
kWh
|
- | |
03 | 2.2437: Recover waste heat from equipment | $1,592 | $61 |
$241
3,810
kWh
|
$1,351
-
MMBtu
|
|
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $29,194 | $42,215 | - |
$29,194
-
MMBtu
|
|
TOTAL RECOMMENDED | $66,226 | $108,491 |
$36,157
329,132
kWh
|
$30,069
-
MMBtu
|
||
TOTAL IMPLEMENTED | $30,786 | $42,276 |
$241
3,810
kWh
|
$30,545
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs