| Assessment Year | 1982 |
|---|---|
| Principal Product | IND. MIXING EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3556: Food Products Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,500
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $114,422 | 2,066,237 |
kWh
|
$0.055 |
| Natural Gas | $87,782 | 20,050 |
MMBtu
|
$4.38 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $40,835 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,835 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,558 | $872 |
$3,233
54,513
kWh
|
$(-675.0)
-
MMBtu
|
|
| 02 | 2.7492: Use proper thickness of insulation on building envelope | $15,588 | $146,250 | - |
$15,588
-
MMBtu
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $2,264 | $8,000 |
$1,004
18,757
kWh
|
$1,260
-
MMBtu
|
|
| 04 | 2.7494: Install storm windows and doors | $20,425 | $29,798 | - |
$20,425
-
MMBtu
|
|
| TOTAL RECOMMENDED | $40,835 | $184,920 |
$4,237
73,270
kWh
|
$36,598
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $40,835 | $184,920 |
$4,237
73,270
kWh
|
$36,598
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs