Assessment Year 1982
Principal Product AUTOMATION MACHINERY
NAICS
n/a
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 267
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 4,200
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $82,577 1,467,175
kWh
Natural Gas $13,060 3,584
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $8,266 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,266

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4221: Install compressor air intakes in coolest locations $229 $400 $229
4,103
kWh
-
02 2.7226: Use computer programs to optimize hvac performance $4,586 $7,000 $4,586
33,705
kWh
-
03 2.7492: Use proper thickness of insulation on building envelope $3,451 $3,100 $713
12,603
kWh
$2,738
-
MMBtu
TOTAL RECOMMENDED $8,266 $10,500 $5,528
50,411
kWh
$2,738
-
MMBtu
TOTAL IMPLEMENTED $8,266 $10,500 $5,528
50,411
kWh
$2,738
-
MMBtu
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs